Meter in Circuitry
January 26, 2016 Comments Off on Meter in CircuitryToday we would like to talk about Relief Valve Settings Meter in Circuitry – speed controlled extentions In the circuit illustrated, the restrictor type pressure compensated flow control valve is set for a 3 GPM. Relief valve setting is 500 PSI. Work load pressure is 200 PSI. The spring biasing the compensator spool has value…