Vickers Flex Plate Hydraulic Double Pumps – Shaft End Outlet Body

Vickers Flex Plate Hydraulic Double Pumps – Shaft End Outlet Body

Vickers Flex Plate Hydraulic Double Pumps – Shaft End Outlet Body

Comments Off on Vickers Flex Plate Hydraulic Double Pumps – Shaft End Outlet Body

Vickers Flex Plate Hydraulic Double Pumps – Shaft End Outlet Body

 

There are two outlet body layouts with two shaft seals that are options for these pumps.  If you have a single pump the steel ball is mashed into the body.  On the double shaft seal units, a plastic plug is used to seal the body off from draining.  And it doesn’t let any contamination in between the seals. The shaft seal ratings are: outer – 7 PSI and the inner is 2 PSI.  When you have a double shaft seal unit, it will have a different design and may not go with other models. It is due to the extra shaft shoulder length so that it makes room for the second shaft seal.

The diagram will show what we are talking about, but if you have questions give us at call at

800-361-0068

sales@hydrostatic-transmission.com