Sundstrand Sauer Danfoss Series 40 Disassembly of Fixed Displacement Motors Part 2
Sundstrand Sauer Danfoss Series 40 Disassembly of Fixed Displacement Motors Part 2
March 1, 2016 Comments Off on Sundstrand Sauer Danfoss Series 40 Disassembly of Fixed Displacement Motors Part 2At our Hydrostatic Pump Repair Site, we offer many types of Hydrostatic Transmission Repair and information relating to Hydrostatic Parts
Today we will discuss:
Part 2 of Disassembly of Fixed Displacement Motor Series 40
Take the thrust plate from the housing.
If you have a date code of 86-23 : The slot in the motor housing was changed in the size of the thrust plate tang in how it went into the slot.
Next take the bearing retaining ring from the housing and the shaft and bearing assembly.
Lastly take the retaining ring from the shaft and press the shaft out of the bearing, along with the second retaining ring from the shaft.
In the diagram it shows these last steps. If you have any other questions on this subject, we will be glad to assist you.
If there is a subject you wished discussed or you need to call us, we will be glad to hear from you.
800-361-0068
Or you can email us your questions, send in pictures or you may need a quote on a unit, repair/rebuild. We can help, just give us a try.
sales@hydrostatic-transmission.com