Sundstrand Sauer Danfoss Series 90 – Feedback Link Retention
Sundstrand Sauer Danfoss Series 90 – Feedback Link Retention
July 27, 2016 Comments Off on Sundstrand Sauer Danfoss Series 90 – Feedback Link RetentionAt our Hydrostatic Pump Repair Site, we offer many types of Hydrostatic Transmission Repair and information relating to Hydrostatic Parts
Today we will discuss:
Sundstrand Sauer Danfoss Series 90 – Feedback Link Retention
In September 1992 the feedback link will be maintained in the swashplate in the past, the link slipped over a certain ground socket head screw and might fall off the screw during assembly. The screw has revamped to include a head to hold on to the link.
The feedback link doesn’t change.
Pumps that have serial number A-92-38-xxxx and beyond have the new element.
If you have any questions, please let us know.
You can call 800-361-0068