Sundstrand Sauer Danfoss Series 90 – Pulse Sensing Change
Sundstrand Sauer Danfoss Series 90 – Pulse Sensing Change
April 12, 2018 Comments Off on Sundstrand Sauer Danfoss Series 90 – Pulse Sensing ChangeAt our Hydrostatic Pump Repair Site, we offer many types of Hydrostatic Transmission Repair and information relating to Hydrostatic Parts
Today we will discuss:
Sundstrand Sauer Danfoss Series 90 – Pulse Sensing Change
Some of the pulse pick ups that are on the pumps and motors between June 1992 and April 1994 were found to be defective. They were corrosion on the internal circultry.
The corrosion of the internal circuitry can have intermittent operation or partial loss of signal and eventual failure.
The picture shows what an installation looks like of the silver color of the potentially defective pulse pick up body. It needs to be replaced with a pulse pick up body that is black in color.
Electrical closed loop feed back circuit, if you have a speed sensor, that is used with a microprocessor, the sliver colored speed sensor need to be replaced even if it has the special hardware features code.
If you need more info on this subject, please let us know.