Sundstrand Sauer Danfoss Series 20 – Neutral Start Switch Check Part 2
Sundstrand Sauer Danfoss Series 20 – Neutral Start Switch Check Part 2
August 2, 2016 Comments Off on Sundstrand Sauer Danfoss Series 20 – Neutral Start Switch Check Part 2At our Hydrostatic Pump Repair Site, we offer many types of Hydrostatic Transmission Repair and information relating to Hydrostatic Parts
Today we will discuss:
Sundstrand Sauer Danfoss Series 20 – Neutral Start Switch Check Part 2
If constancy can not be made sure of in neutral, then you will need to decide the direction of the handle rotation make sure it is to constant.
The pin which immerses in the slot is mounted in an eccentric that allows for adjustment. It is suggested than an adjustment tool be constructed to the dimensions show on diagram.
While you have the switch, loosen the switch locknut and take the neutral start switch. The slotted eccentric adjustment within the switch collar. Loosen the locknut while holding the eccentric in the place with the adjustment tool.
Try not to start the prime mover while the neutral start switch is take out of the control. Damage to the control will result.
If you have any questions, please give us a call.
800-361-0068