Hydraulic Circuitry
Hydraulic Circuitry
February 15, 2016 Comments Off on Hydraulic CircuitryAt our Hydrostatic Pump Repair Site, we offer many types of Hydrostatic Transmission Repair and information relating to Hydrostatic Parts
today we will discuss:
Hydraulic Circuitry – Feed Type Circuit
It is at this point in the circuitry, that the cam connected to the cylinder actuates the deceleration valve. As the cam depresses the plunger, flow the the valve is gradually cut off. This valve allows a load attached to the cylinder rod to be slowed down at any point of its stroke, where cylinder cushions are not in effect. Fort the remainder of the stroke, oil leaving the head end will pass the the flow control valve (set at the necessary feed rate) thru the directional control and back to tank. It should be noted that the relief valve has opened because flow control has now become apparent to the circuitry.