Rexroth Variable Pump A10V0 Series 31 Offset-able Pilot Pressure Control
Rexroth Variable Pump A10V0 Series 31 Offset-able Pilot Pressure Control
September 26, 2018 Comments Off on Rexroth Variable Pump A10V0 Series 31 Offset-able Pilot Pressure ControlRexroth Variable Pump A10V0 Series 31 Offset-able Pilot Pressure Control
DRT1/2 is offset-able by pilot pressure. Without the pilot pressure is the system is on standby (25 bar). With the pilot pressure the pump pressure is expanded by the transmission factors DRT1 or DRT2. This is made for load pressure control and is for mobile machinery procedures. The main spool is hydraulically actuated and the pump pressure that was picked by means of the pilot transmitter
Transmission factors
DRT1 1= 18.2
DRT 2 1=12.4
If you need further info on this, call us at 800-361-0068